OPTIONS

•  Ø 2 1/16’’ - L138mm
•  Ø 3 1/16’’ - L138mm
•  Ø 4 1/16’’ - L138mm
•  OLED display 2x14 Segment
•  Stand alone battery operation
•  Wireless HART/WiFi IEEE 802.11
iBP* - INSTRUMENTED BARRIER PLUG

CONTINUOUS ANNULUS P/T MONITORING
• NORSOK D-010 CONTINUOUS MONITORING
• NORSOK I-001 PROCESS ISOLATION
• API 6A /FA METAL BARRIERS WITHOUT PENETRATIONS
INSTRUMENT

•  2 1/16’’ API 6A 104 MPa [15 kpsi]
•  Metering pressure 104 MPa [15 kpsi]
•  Metering temperature -20…100°C [-4… 210°F]
•  Set and retrievable without need for special tools
•  NORSOK D-010 WELL INTEGRITY
•  NORSOK I-001 INSTRUMENT
•  ISO 13628-6 ENVIRONMENT
•  ATEX / IECEX Sone 1/0 (PED)
•  0-1034 Bar [15 kpsi]
•  -40..200°C [-40...400°F]
•  HP/HT COMPLIANT
•  2 1/16”... 4 1/16” Sizes
•  24VDC Power or battery operation
•  Wired 4...20mA, 0...10V, 1...5V
•  Wired multidrop RS485 Modbus/ ProfiBUS
•  API 6A
•  ISO 13 628-6
•  CE PED
•  ATEX II 2G EEx d IIC T6 [85°C] U IP66 (House)
•  ATEX II 1G EEx ia IIC T6 [85°C] U IP6X (Instrument)
The iBP apparatus and associated technology is protected by national and international patents
*iBP currently not available for sale in Norway